Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Telefoonkabels

 PE/PVC Insulated Parallel Drop Wires to RUS (REA) PE-7

Aanvraag

The drop wires are designed for use in extending telephone circuits to subscriber premises by means of an aerial drop from distribution wire or cables. The shape may be in oval/dumbbell shape to aid in separation of conductors.

Normen

 

• RUS (REA) PE-7


• ASTM B227, B452 & B1

 

Bouw

Dirigenten
Two conductors made of 0.9/1.0/1.023mm copper covered steel wires serve dually as conductor and strength members

Bonding
Bonding of the insulation to the conductors is made to assure the full conductor strength is transferred to the wire support clamps

Isolatie
Conductors are laid in a parallel configuration and covered with low density or medium density polyethylene (PE) or polyvinyl chloride (PVC)

Elektrische eigenschappen

Nominal Conductor Diameter

mm

0.9

1.0

1.023

Conductor Gauge Size

AWG

19

18.5

18

Conductor Size

mm2

0.636

0.785

0.827

Minimum Insulation Resistance @500V DC

MΩ.km / MΩ.kft

30/100

30/100

30/100

Dielectric Strength Conductor to Conductor(3secs)

V DC

7050

7050

7050

Nominal Insulation Thickness

mm/inch

1.02/0.039

1.02/0.039

1.02/0.039

Nominal Insulated Conductor Diameter

mm/inch

2.94/0.116

3.04/0.117

3.06/0.118

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Afmetingen en het gewicht

Kabel-code Number of
Cores
Isolatie
materiaal
Nominale isolatiedikte
mm/inch
Nominal Overall Dimensions
mm/inch
Nominale Gewicht
kg/km / lbs/kft
1.023mm Conductor, 3.06 Insulated Wire

TP7-2Y-1P18A-SS

2

PE

1.02/0.04

3.0x7.0/0.11x0.28

32/22

TP7-Y-1P18A-SS

2

PVC

1.45/0.06

3.9x7.6/0.15x0.30

49/33

1.0mm Conductor, 3.04 Insulated Wire
TP7-Y-1P18/5A-SS 2 PVC 1.02/0.04 3.9x7.4/0.15x0.29 46/31
0.9mm Conductor, 2.94 Insulated Wire
TP7-2Y-1P19A-SS 2 PE 1.02/0.04 2.9x7.7/0.11x0.30 25/17